high pressure filter, filteration, pressure gauge, manual drain valve Contact Us Site Map  
 
  high pressure filter, filteration, pressure gauge, manual drain valve
About Us Our Products Our Clients Our Services Career
   High Pressure Filter
 
  Operating Pressure : up to 400 Bar g, Op Temp 6° C.  
  Material : Housing, Aluminum, Carbon Steel, S.S.304 or S.S.316/SS316L.  
 
Elements:
SF Sintered Bronze.
PF GF,HF High Efficiency, Binder free micro glass fiber.
CF Fine Activated Carbon.
 
     
 

Table I : Flow capacities - 7 Bar Op. Pressure

 
 
  Nominal Max. Conn.Size Element Code
  NM3/Hr. SCFM NM3/Hr.

SCFM

   
003 HP 30   60 33.41 R ½" 0211
006HP 60   90 50.11 R ½" 0311
009HP 90   120 66.82 R ¾" 0411
012HP 120   180 100.22 R1" 0411
 
     
 

Table II : Pressure Conversion Factor

 
 
OP.pr Bar(g) 7 25 50 100 150 300 400
Pr. Factor 1 3.25 6.4 12.7 12.7 12.7 12.7
 
     
 

To complete model no. insert model after filteration grade

 
Example : Combination SF + HF 003HP.  
 
SIZING : Determine operating temperature & pressure (maximum & minimum) & flow rate at the location where filter is to be installed. Select filter with rated flow capacity on basis of maximum flow at minimum operating pressure. Rated flow from Table I should be multiplied by conversion factor from Table II corresponding to minimum pressure to match desired flow rate.

Also select housing connection size that matches with pipe size. If filter Connection size is smaller than piping, flow will be restricted causing Increased pressure drop.

 
     

FILTERATION GRADE SELECTION :

 
 

Determine end use application of air to be filtered i.e. tools, instrumentation, Process air. Choose grades which will meet the specifications for your application. Please contact your local dealer or factory with complete information regarding Flow rate, operating pressure, temperature & end use of air.

 
     

OIL REMOVAL GRADES :

 
  For maximum removal efficiency install filters at coolest point in system. Filters will operate at higher temperature but at reduced efficiency.  
     
ELEMENT REPLACEMENT :  
 

Change elements before differential pressure reaches 0.7bar g (10psig). Grade SF can be cleaned & reused. Other grade require replacement according to operating conditions. Grade CF must not operate in oil saturated conditions & should always be proceeded by SF/HF grade element filter.

 
     
OPTIONAL ACCESSORIES :  
 

Differential pressure gauge & Manual Drain Valve. For higher flow rates, higher pressure or special filteration grades with complete data such as flow rate, Op. Pr. & temp. micron rating, desired line size etc. Please contact Head Office.

 
 
 
Home | About us | Products | Clients | Services | Career | Contact Us
 
Copyright © 2006 Southwest Compressor Technologies Pvt. Ltd.       Site powered byikf.co.in