compressed natural gas filter, separators, low pressure drop Contact Us Site Map  
 
  compressed natural gas filter, separators, low pressure drop
About Us Our Products Our Clients Our Services Career
    Compressed Natural Gas Filter
compressed natural gas filter, separators, low pressure drop
 
     
COMPRESSED NATURAL GAS FILTER  
 
Housings are designed for effective separation & low pressure drop.
High separating efficiency thus consistent gas quality.

Element has high contamination retention capacity & low pressure drop resulting in energy savings & in cost saving.

Choice of elements assures desired gas quality at optimum cost.

To be used as fine filter for natural gas installations.

Housings are warranted against design, manufacturing, material & workmanship defect for five years and elements for one year.
 
 
  Specifications:
 
Max. Op. Pressure : 20 Bar Pressure Drop Nominal 0.150 Bar / Max. Allow 1 Bar
Max. Op. Temp : 60 Deg. C Material Body Carbon steel
Micron rating : Porous down to 5 micron End Connections Flanged ANSI B 16.5 RF (S) 150 #
Efficiency : 99.997% at 25 Um Hydro test Pr. 30 Bar g
Elements : Sintered Bronze / S.S Wire mesh    
 

 
Table 1 : Flow capacities - 1.4 Bar Op. Pressure
Model Flow in NM3/hr End Conn. Element
  Nomina Max. Flgd. to ANSI B 16. Code No
NGF 006 18

27

½" SF 0311
NGF 009 27 36 ¾" SF 0412
NGF 012 36 54 ¾" SF 0412
NGF 018 54 81 1" SF 0512
NGF 027 81 108 1" SF 0513
NGF 036 108 144 1 ½" SF 1013
NGF 048 144 216 1 ½" SF 1513
NGF 072 216 324 2" SF 2013
NGF 108 324 432 3" SF 3013
NGF 144 432 576 3" SF 2023
NGF 192 576 864 4" SF 2033
NGF 288 864 1296 4" SF 3023
Table 2 : Conversion Factors for different pressures
Op. Pr. in Bar
1.0 0.8
1.4 1.0
2.0 1.25
2.5 1.45
3.0 1.66
3.5 1.87
4.0 2.08
   

Flow Capacities :

 
To determine max. flow capacities at inlet to filter other than 1.4 Bar g Op. Pr. multiply inlet flow from table 1 by conversion factor from table 2 that corresponds to system pr. at inlet to filter.
   

INSTALLATION :

 

Install these separators at the coolest place or immediately after the coolest place for the best performance & higher operating efficiency.

   
MAINTENANCE :
 

These filters being high efficiency units hence more moisture is collected. Regularly drain the moisture or moisture may be carried to outlet. It is recommended to install electronic drain valve for condensate removal automatically. Filter elements can cleaned by using diluted acetic acid 20% concentrated free from nitric acid, wash with hot water and blow cleaned compressed air in reverse direction.

 
 
 
Home | About us | Products | Clients | Services | Career | Contact Us
Copyright © 2007 Southwest Compressor Technologies Pvt. Ltd.       Site powered by ikf.co.in