   After Cooler
after cooler, copressed air system, moisture separator, automatic drain valve
 
General :
 


This is the most important equipment in compressed air system at the same time most neglected one, which controls moisture entry in to operating area. In context of Indian Humid and dusty environment it has great importance. If overlooked or ignored then it makes you run like anything without being suspicious about it. If properly treated then it is very good friend.

It's function is to cool compressed air to ambient temperature. The type of coolers are air cooled and water cooled.

Air cooled cooler consists of nest of finned tubes through which compressed air flows and over which a forced draught of cold air passed by means of fan assembly. Normally outlet air temperature is 12 to 15 deg C over ambient temperature for properly designed coolers.

In water cooled after cooler steel shell houses nest of tubes with water circulating either inside or outside tubes with compressed air on the other side, usually arranged so that their flow is in opposite direction through the cooler. With water cooled cooler it is possible to ensure that the temperature of the outlet air is no more than 10 deg C above cooling water inlet temperature.

 
   
 
Installation :
  Install after cooler near to compressor with clean and treated water supply and effective cooling for re-circulating water.
   
Scope of Supply :
  All after cooler shall be fitted with moisture separator for effective moisture separation and optional automatic drain valve for collected moisture discharge to drain line.
   
Standards :
  IS4503, IS2825, TEMA B ,TEMA C , ASME Sec VIII Div I or as per customer specifications.
   
Material :
  IS2062, SA 515Gr 70, SA106 Gr B Copper tubes.
   
Operating Pressure :
  7 to 16 Kg /cm2 g.
   
Capacity :
  40 Nm3/Hr to 5,000 Nm3/Hr.

After Cooler
After Cooler
Optional Tests :
 
Material :

Physical & Chemical tests.

 

Welder's Qualification in presence of customer if needed.

Weld Examination: Dye Penetrant.
 

X ray/ gamma rays.

  Magnetic particle.
  1.5 times max operating pressure or design pressure.
   
Hydro Testing
 

For your specific requirement of after cooler to meet either your process requirements, or pressure, or material or design standard or inspection requirements please contact or write to registered office.

   
 
 